Przeglądanie stron 70
RPC-6022GW Rackmount LCD Workstation
Page 71
Step 9:
Step 10:
Step 1:
Step 2:
Step 3:
Step 4:
Reinstall the CPU card clamp.
Close the top cover of the workstation and reinstall the workstation into the
cabinet or rack in which it was previously installed. Refer to Section 4.6 for
complete mounting instructions. Step 0:
5.7 Cooling Fan Replacement
To replace a cooling fan, please follow the instructions below.
CAUTION:
Carefully note the direction and orientation of the existing cooling fan prior to
replacement.
Turn off and disconnect the workstation from all power sources.
Remove the workstation from the rack in which it is installed.
Open the top cover of the RPC-6022GW Rackmount LCD Workstation.
(See Section 4.5.1)
Disconnect the cooling fan from the PSU (Figure 5-4).
Figure 5-4: Disconnect the Cooling Fan
Przeglądanie stron 70