8.3.1 Refresh Time Setting
The iSMM refreshes the voltage values according to the refresh time period set by the
user. Follow the steps below to set the refresh time:
Step 1: Click on the Voltage Page tab.
Step 2: Entering a value beside the Refresh time (Sec) (
964HFigure 8-5).
Step 3: Click apply (
965HFigure 8-5). Step 0:
Figure 8-5: Voltage Refresh Time Setting
8.3.2 High Limit Value and Low Limit Value Setting
The high limit value and low limit value of each voltage can be set by the user. When the
voltage is greater than the high limit value or less than the low limit value, the voltage
value shows in red. For example, the VBAT voltage (3.22V) shows in red in
966HFigure 8-4
since the current VBAT voltage is greater than the high limit value (3.2V).
To set the high limit value or low limit value, follow the steps below.
Step 1: Double click a high limit value or a low limit value to enter the new value (
967HFigure
8-6).
Figure 8-6: Voltage Page – High Limit and Low Limit