SAILORPC-12A Panel PC
Page 55
19200 8,n,1
09600 8,n,1
NOTE:
Identical baud rate setting musts be set on the host (a management
computer running a terminal software) and the slave
Flow Control [None]
Use the Flow Control option to report the flow control method for the console redirection
application.
Î
None DEFAULT
No control flow,
Î
Hardware
Hardware is set as the console redirection
Î
Software
Software is set as the console redirection
Redirection After BIOS POST [Always]
Use the Redirection After BIOS POST option to specify when console redirection should
occur.
Î
Disabled
The console is not redirected after POST
Î
Boot Loader
Redirection is active during POST and during Boot
Loader
Î
Always DEFAULT
Redirection is always active (Some OSes may not
work if set to Always)
Terminal Type [ANSI]
Use the Terminal Type BIOS option to specify the remote terminal type.
Î
ANSI DEFAULT
The target terminal type is ANSI
Î
VT100
The target terminal type is VT100